D and G: Particulate Testing

This chapter defines the scale, dose, procedure and grading shared by the D (dust) and G (grit) groups. The two groups differ only in their test medium and full dose, which are defined in their own chapters.

Exposure area

A = sum of (length × width) of the largest face of each rigid section, in cm²
Device typeRigid sectionsA
Slab phone or tablet1Front face
Book-style foldable2Both halves (equals the unfolded face)
Flip-style foldable2Both halves
Laptop2Base + lid

Note (informative): Dose scales with exposure area, not mass. Particles get in through surfaces, seams and moving parts, so a dense device and a light device of the same size have the same exposure. Devices with hinges receive a larger dose automatically, in proportion to their extra surfaces and seams.

Dose

Dose (g) = (A ÷ 100) × F × p
SymbolMeaning
AExposure area, cm²
FFull dose per 100 cm², set per group: D, G
pCumulative fraction of the full dose for the level (see Scale)
  1. Every dose shall be weighed. The weighed mass is the dose.
  2. Volume measures may be used as rough guidance only (see Volume Conversions).

Note (informative): Powders pack differently depending on the product and how they are scooped. One tablespoon (15 mL) of dry sand weighs roughly 23 g, but a tablespoon of fine powder can weigh anywhere from about 5 to 15 g. This is why doses are weighed rather than measured by volume.

Example doses (informative)

DeviceAD, lvl 1D, lvl 5D, lvl 9G, lvl 1G, lvl 5G, lvl 9
Phone, 16 × 7.5 cm120 cm²0.6 g7.5 g30 g2.4 g30 g120 g
Book foldable, 16 × 12.5 cm unfolded200 cm²1.0 g12.5 g50 g4.0 g50 g200 g
Tablet, 24 × 17 cm408 cm²2.0 g25.5 g102 g8.2 g102 g408 g

Scale

Levels are cumulative: each level adds more medium and more cycles on top of the previous level, with no cleaning in between.

LevelSeverityCumulative dose (p)Cumulative cycles
0Failed level 1n/an/a
1Trace2%10
2Trace5%20
3Light10%30
4Light15%50
5Moderate25%75
6Moderate35%100
7Heavy50%150
8Heavy75%200
9Buried100%250

For each level, the dose increment shall be the difference between that level’s cumulative dose and the previous level’s, and the cycles run shall be the difference between their cumulative cycles.

Note (informative): Cumulative levels reproduce debris building up over time.

Cycle

One cycle means operating every moving part through its full range once, at about one cycle every 2 seconds:

Moving partOne cycle
Hinges and slidesFully closed to fully open and back
Buttons and keysPressed once each. For keyboards, a fixed set of keys defined in the report
Crowns and dialsOne full turn each way
Port covers and traysOpened and closed once every 10 cycles
PortsA plug inserted and removed once every 10 cycles

Procedure

Procedure steps are written in the imperative and are requirements unless they say otherwise. Equipment is listed in Kits and safety requirements in Safety.

Before testing

  1. Confirm the unit meets Test Conditions, including its baseline for this group.
  2. Measure the exposure area and calculate the dose for every level.
  3. Home tier: the tester may choose a maximum level in advance.

Each level

  1. Weigh the dose increment for this level.
  2. Place the unit on the raised rack inside the bin, in its most open state (hinged devices fully open; slab devices front face up). The rack shall hold the unit clear of medium that has fallen to the bin floor.
  3. Apply half the increment, sprinkled evenly from about 10 cm above. The medium may be shaken through the #20 sieve to give an even spread.
  4. Brush each seam, hinge line and port opening with 5 light strokes.
  5. Run half the level’s cycles.
  6. Turn the unit over on the rack (hinged devices: close it). Apply the other half of the increment to the exposed faces, edges and ports, brush, and run the remaining cycles.
  7. Shed loose material: hold the unit edge-down and tap it 3 times on each long edge onto a folded towel. Do not blow or wipe the seams at this stage.
  8. Measure every applicable effect (see Measurements) and record the results.
  9. Grade the level (see Grading) and decide whether to continue (see Stop rules).

Note (informative): Without the rack, a unit turned over in step 6 would lie in the medium that fell during the first half, so its real dose would depend on the size of the bin.

Stop rules

TierContinue to the next level unless…
HomeAny effect other than i appeared at this level, the chosen maximum level was reached, or level 9 was completed
LabThe level was failed (an uppercase effect appeared), or level 9 was completed

Note (informative): Home testers stop at the first sign of degradation to give the device the best chance of surviving.

After testing

WhenRequirement
After D and after G, both tiersBetween-group cleaning
After the last group, lab tierTeardown

Grading

  1. A level is passed if no uppercase effect appeared after it.
  2. The digit is the highest level passed (0 if level 1 failed).
  3. Effect letters and the failure letter shall be written per Code Format, including the failure-letter priority order and the meaning of an absent failure letter.
  4. Enclosure breaches found at teardown are handled per Test Tiers.

Examples (hypothetical)

CodeTierMeaning
D5rHomePassed moderate dust; rough motion appeared at level 5, so testing stopped to protect the device
G3HomePassed light grit with no effects; the tester’s chosen maximum was 3
D9LabPassed buried fine dust with nothing getting in
D7iELabPassed heavy fine dust with dust visible inside openings but no effect; electrical fault at level 8
G6rCLabPassed moderate grit with rough motion; at level 7 the hinge would not close
G3hrRLabPassed light grit with loosened hold and rough motion; at level 4 the hinge bound