Test Tiers

IDR has two test tiers:

  • Home: for an individual testing one device they intend to keep.
  • Lab: for testers who can sacrifice and tear down two or more devices.
HomeLab
Units12 or more
Device fateKept: the tester intends to keep it workingSacrificed
Device conditionAny, from new to heavily used; shall be recorded as foundShall be spread across wear: one new, one heavily used (real or simulated), and further units filling in the levels between
U digitPer unit conditionPer unit condition
LaddersStop at the first effect, or at the tester’s chosen maximum (D and G, W)Run to failure or the top (D and G, W)
CleaningBetween groups and after the last groupBetween groups
TeardownNoYes, every unit, after the last group tested
Can detect enclosure breach (E)Electrical faults onlyYes
Code prefixIDR1* (see code format)IDR1
Published codesOne full codeOne full code per unit, plus a headline code
IDRS short codeCannot be issuedCan be issued (IDRS)

Note (informative): Home results are useful for comparing devices and spotting weak points, but they cannot confirm sealing. This is why the * marks them as never equivalent to lab results.

Lab tier: teardown

After the last group tested, every lab-tier unit shall be torn down as follows.

  1. Tear down the unit. Inspect each sealed compartment for debris and liquid, and photograph it under UV light.
  2. Record the state of every liquid contact indicator the device has.
  3. Inspect hinge and mechanism internals for debris, scoring and damaged parts. Photograph and describe them.
  4. Record any enclosure breach with its location, and attribute it (see below).

The exterior UV photographs taken after D (see Between-group cleaning) form part of the teardown record.

Attributing an enclosure breach

Evidence inside a sealed compartmentAttributed to
UV-fluorescent debris (traced D medium)D
Non-fluorescent sand grains in the G medium’s size rangeG
Liquid, water marks, corrosion, or a tripped liquid contact indicatorW
  1. Every group whose evidence is found shall be attributed.
  2. If the evidence does not identify a group, every group tested on that unit shall be attributed.
  3. Each attributed group’s result for that unit shall be marked unverified in the report. The code digit stands as tested.
  4. No IDRS digit for an attributed group shall be taken from that unit (see IDRS Short Code).

Note (informative): A teardown cannot show at which level or step a breach happened, which is why the result is marked unverified rather than regraded. Water can also carry D medium further into the device, so a D breach found after W may have been helped by the water. See Open Issues.