W: Water
What W tests
W tests resistance to fresh water at increasing depth and duration, with moving parts operating.
Medium
- W tests shall use fresh, potable tap water.
- Distilled, deionized, salt and pool (chlorinated) water shall not be used.
- Water temperature shall be recorded at each step.
Note (informative): Distilled and deionized water conduct electricity poorly and can hide electrical faults that tap water would cause. Salt and pool water are planned as future groups.
Scale
W is graded on two scales.
| Depth tier | Depth |
|---|---|
| 1 | Spray / splash |
| 2 | 1 m |
| 3 | 2 m |
| 4 | 4 m |
| 5 | 6 m |
| Time tier | Duration |
|---|---|
| 1 | 10 min |
| 2 | 30 min |
| 3 | 1 h |
| 4 | 4 h |
Ladder
A step is one exposure at one depth tier for one time tier. Steps run in this order:
| Order | Depth tier | Time tiers, in order |
|---|---|---|
| 1 | 1 | 1, 2 |
| 2 | 2 | 1, 2 |
| 3 | 3 | 1, 2 |
| 4 | 4 | 1, 2 |
| 5 | 5 | 1, 2 |
| 6 | The deepest depth tier tested | 3, 4 |
- Each step shall be a separate exposure.
- Time tiers 3 and 4 shall be run only at the deepest depth tier tested, and never at depth tier 1.
Note (informative): Steps are cumulative, like D and G levels: each exposure adds to the ones before it. Running time tier 2 at every depth lets the IDRS water digit be derived from the report.
Stop rules
| Tier | Continue to the next step unless… |
|---|---|
| Home | Any effect other than i appeared at this step, the chosen maximum was reached, or the last step was completed |
| Lab | The step was failed (an uppercase effect appeared), or the last step was completed |
Procedure
Procedure steps are written in the imperative and are requirements unless they say otherwise.
Before testing
- Confirm the unit meets Test Conditions, including its W baseline.
- Home tier: the tester may choose a maximum depth tier and a maximum time tier in advance. Only depth tiers the tester can physically perform may be claimed.
Each step
- Expose the unit.
- Depth tier 1: spray or splash, by a method [TBD].
- Depth tiers 2–5: immerse the unit with its lowest point at the tier’s depth. The lab tier may instead use a pressure vessel at the hydrostatic pressure of fresh water at that depth.
- Cycle moving parts during the exposure, [TBD] cycles per step (see cycle). If the unit cannot be reached (for example, in a pressure vessel), run the cycles immediately before and immediately after the exposure, and record this in the report.
- Hold for the time tier’s duration.
- Remove and dry the exterior: shake out water and wipe with a lint-free cloth. Do not use heat or compressed air.
- Measure every applicable effect (see Measurements). Measure
mafter the drying period [TBD]. - Grade the step (see Grading) and decide whether to continue (see Stop rules).
After testing
| Tier | Requirement |
|---|---|
| Home | Leave the unit to dry for the drying period [TBD] before charging (see Safety) |
| Lab | Teardown |
Grading
- W shall be written
W{depth}{time}. - A step is passed if no uppercase effect appeared after it.
- The depth digit is the deepest depth tier whose time tier 1 step was passed.
- The time digit is the longest time tier passed at that depth tier.
- A unit that fails the first step shall be written
W0with its failure letter and no time digit. - Effect letters record the effects present after the rated step, per Code Format.
- The failure letter names the failure at the next step on the ladder, per Code Format.
Examples (hypothetical)
| Code | Meaning |
|---|---|
W52E | Passed 6 m for 10 and 30 minutes; electrical fault at 1 h |
W22F | Passed 1 m for 10 and 30 minutes; fogging beyond tolerance at 2 m, 10 minutes |
W31F | Passed 2 m for 10 minutes; fogging beyond tolerance at 2 m, 30 minutes |
Water-specific effects
| Letter | Effect |
|---|---|
f | Fogging or condensation inside a lens or display |
m | Audio impaired after the drying period [TBD] |
Thresholds for both are in Effect Letters.